DuraLabel 9000 Guía de usuario Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 53
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
C. Cont. Mode
30
Press or to scroll the cursor to the sensor type. Press to
enter the black-mark sensor calibration mode.
C-1 Automatic
When entering the [Automatic] option, you will see following message and
the printer will calibrate the sensor sensitivity automatically. When
calibration process is completed, the LCD screen will return to the previous
menu.
C-2 Manual
In case “Automatic” sensor calibration cannot apply to the media, use
“Manual” function to calibrate the sensor manually.
When you enter [Manual] option, you will see following message. Please
complete these three steps:
Cont. Mode
Remove Label
Intensity x
Ref. Level xxx
1. Remove the label supply. Press
to set the value into the
printer.
Cont. Mode
Scan Paper
Intensity x
Ref. Level xxx
2. Put the label supply under the media
sensor. Press
to set the
value into the printer.
Calibration 3/4
Bline Mode
> Cont. Mode
Exit
Cont. Mode 1/3
> Automatic
Manual
Exit
Cont. Mode
Automatic
Cont. Mode 2/3
Automatic
> Manual
Exit